廊坊地基微波辐射计大气温湿廓线反演产品评估分析
作者:
作者单位:

作者简介:

沈芳,女,助理工程师,主要从事天气预报工作,1506150715@qq.com。

通讯作者:

中图分类号:

P413.2

基金项目:

河北省廊坊市气象局科研项目(202105)


请扫码阅读

Evaluation and analysis of retrieval products of atmospheric temperature and humidity profiles from ground-based microwave radiometer in Langfang
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    利用2017—2020年廊坊市大厂县QFW-6000型微波辐射计和北京探空资料,对08时和20时2个时次共737组有效样本垂直方向的气温、湿度进行对比检验。结果表明:(1)整层气温均方根误差在5 ℃以内,相对湿度均方根误差为20%~30%,气温的相关系数明显高于相对湿度,即前者的探测精度更高。(2)1 km以下08时和20时温度和相对湿度的误差差异显著,08时误差均小于20时,1 km以上气温误差稳定在3 ℃左右,相对湿度误差廓线随高度先增大后减小。(3)夏秋季温度误差总体小于春季和冬季,但夏季贴地层误差明显大于其他季节,而相对湿度误差在冬季更为稳定。(4)晴天微波辐射计的探测精度明显优于云天和雨天,且随着云量的增多,探测精度逐渐下降。(5)降雨量级的差异对微波辐射计的探测精度产生不同影响,雨量越大,温度和相对湿度的误差越大;小雨时温度的相关系数在贴地层以上为0.60~0.90,但整层相对湿度的相关系数普遍在0.50以下,中雨及以上的降雨出现时,08时和20时温度的相关系数表现出显著差异,而相对湿度的相关系数在大雨及以上时波动最大,表现出极不稳定的探测性能。

    Abstract:

    Using the QFW-6000 microwave radiometer data of Dachang County, Langfang City and the radiosonde data of Beijing from 2017 to 2020, the temperature and humidity in the vertical direction of 737 groups of effective samples at 08:00 and 20:00 are compared and tested. The results are shown below. (1) The root mean square error of temperature in the whole layer is within 5 ℃, and the root mean square error of relative humidity is 20%-30%. The correlation coefficient of temperature is significantly higher than that of relative humidity, that is, the detection accuracy of the former is higher. (2) The errors of temperature and relative humidity at 08:00 and 20:00 below 1 km are significantly different. The errors at 08:00 are less than those at 20:00 and the errors of temperature above 1 km are stable at about 3 ℃. The error in relative humidity profile first increases and then decreases with height. (3) The temperature errors in summer and autumn are generally smaller than those in spring and winter, but the error in the ground layer in summer is significantly greater than those in other seasons, and the error of relative humidity is more stable in winter. (4) The detection accuracy of the microwave radiometer in sunny days is obviously better than those in cloudy and rainy days, and with the increase of cloud cover, the detection accuracy gradually decreases. (5) Different rainfall intensity has different effects on the detection accuracy of microwave radiometer, and the greater the rainfall, the greater the errors of temperature and relative humidity. The correlation coefficient of temperature during light rain ranges from 0.60 to 0.90 above the ground layer, but the correlation coefficient of relative humidity in the whole layer is generally below 0.5; when moderate rain or above occurs, the correlation coefficient of temperature at 08:00 and 20:00 shows significant differences, while the correlation coefficient of relative humidity shows the biggest fluctuation in heavy rain or above, showing extremely unstable detection performance.

    参考文献
    相似文献
    引证文献
引用本文

沈芳,黄浩杰,周玉都,许敏,张湘涵.廊坊地基微波辐射计大气温湿廓线反演产品评估分析[J].海洋气象学报,2023,43(4):71-83.